Kev taw qhia txog khoom
HTS-A series industrial chiller feem ntau yog siv rau hauv kev lag luam Yas & Roj Hmab; Nws tuaj yeem tswj tau qhov kub ntawm molding thiab ua kom lub voj voog molding luv dua, ua kom cov khoom zoo dua thiab txhim kho kev ua haujlwm ntau lawm. Lawv kuj siv dav hauv kev ua haujlwm hlau, Mechanical & Engineering, Chemical & Pharmaceutical, Food & Beverage, Laser, Electronics industry, Textile, Electroplate, Semi-conductor testing, Water jet, Vacuum coating, Construction thiab Military.
Tsis yog txhua lub tshuab cua txias zoo ib yam. Yog xav kom txias tau zoo thiab ua haujlwm tau ntev, koj tuaj yeem vam khom rauHERO-TECHntawm Cov Khoom Siv Txias rau txhua yam koj xav tau txias.
HERO-TECH ib txwm nthuav qhia cov kev pabcuam tsim nyog, zoo tshaj plaws thiab kev daws teeb meem.
Daim Ntawv Thov
Kev txias uas ntseeg tau, siv tau ntau yam, thiab ua haujlwm tau zoo.
HERO-TECH chillers xa cov txiaj ntsig rau ntau yam kev siv nrog cov kev xaiv txuag hluav taws xob zoo dua.
Nruab nrab thiab loj industrial txias
Lub tshuab cua txias hauv nruab nrab
Chav txias, chav thermostatic
Cov yam ntxwv tsim
Lub npe nrov Compressor
Chav tsev siv lub teb chaws Yelemees BITZER lossis Taiwan HANBELL hom semi-hermetic ntsia hlau compressor. Qhov tseeb tshaj plaws 5 txog 6 patented ntsia hlau rotor profile nrog kev ua haujlwm zoo heev.
Kev tswj hwm lub peev xwm tsis kawg lossis ze ze, muaj zog txuag hluav taws xob, ruaj khov thiab ntsiag to.
Cov txheej txheem tsim khoom siab tshaj plaws uas tau txais daim ntawv pov thawj siab tshaj plaws.
Kev saib xyuas thiab tiv thaiv ntse tag nrho suav nrog kev saib xyuas qhov kub ntawm lub cev muaj zog, kev saib xyuas theem, kev kaw qhov pib dua tes, lub ntsuas kub roj.
Ntau hom refrigerant rau kev xaiv, suav nrog R134A, R407c thiab R22 (R404A, R507c thaum thov).
Kev Tswj Xyuas Microprogramming
Kev lag luam PLC centralized tswj ua ke nrog compressor peev xwm tswj system, precisely saib xyuas.
Kev tiv thaiv sib xyaw rau qhov kub qis, siab/qis siab, tiv thaiv kev khov, theem ploj lawm, tiv thaiv theem, overload, lub cev muaj zog kub dhau, roj sib txawv, hloov pauv dej ntws, pib qeeb.
Cov lus xaiv ua haujlwm, cov ntawv qhia zaub mov ua tus thawj coj, lub xeev khiav ntawm chav tsev yooj yim kho.
Kev Teeb Tsa Yooj Yim, Kev Khiav Txhim Khu Kev Ntseeg Siab
Kev pib ua haujlwm ze ze, txo qhov cuam tshuam rau hluav taws xob.
Kev khiav ruaj khov thiab muaj kev nyab xeeb, kev co qis, yooj yim rau kev teeb tsa.
Cov qauv compact, qhov chaw tsawg dua thiab lub teeb nyob rau hauv qhov hnyav, yooj yim rau kev thauj mus los thiab kev teeb tsa.
Tau txuas hluav taws xob tag nrho, kuaj xyuas thiab sim ua ntej xa khoom, txuag lub sijhawm teeb tsa thiab tus nqi.
· W-puab txhuas fin hom condenser, ua kom muaj chaw sib pauv cua sov txaus hauv qhov me me
· Cov evaporator ua haujlwm tau zoo nrog lub raj tooj liab sab hauv.
· Lub kiv cua axial loj nrog cov hniav hlau. Lub cev muaj zog sib cais los ntawm lub hau ntawm lub vas, kho rau ntawm qhov chaw tso pa tawm los ntawm hlau
· Siemens PLC tswj, LCD kov npo interface.
· Tus qauv tsim them R22, CFC Dawb R407C, R410A, R404A, R134A rau kev xaiv.
·380V-415V/50Hz 3pH rau tus qauv tsim. Tsim sib txawv raws li cov neeg siv khoom thov.
Kev pabcuam dav dav
-Pab Pawg Ua Haujlwm: Pab pawg engineering nrog qhov nruab nrab 15 xyoo ntawm kev paub hauv kev lag luam tub yees, pab pawg muag khoom nrog qhov nruab nrab 7 xyoo ntawm kev paub, Pab pawg kev pabcuam nrog qhov nruab nrab 10 xyoo ntawm kev paub.
-Kev daws teeb meem tshwj xeeb yeej ib txwm muab raws li qhov xav tau.
-3 kauj ruam kev tswj xyuas zoo: kev tswj xyuas zoo tuaj, kev tswj xyuas zoo ntawm cov txheej txheem, kev tswj xyuas zoo tawm.
-12 lub hlis lav rau txhua yam khoom. Hauv warranty, txhua qhov teeb meem tshwm sim los ntawm qhov tsis zoo ntawm lub chiller nws tus kheej, kev pabcuam muab kom txog thaum qhov teeb meem daws tau.

Tsib qhov zoo ntawm HERO-TECH
• Lub zog ntawm hom lag luam: Peb yog cov kws tshaj lij thiab cov neeg muab khoom zoo tshaj plaws ntawm cov tshuab cua txias hauv kev lag luam nrog 20 xyoo ntawm kev paub dhau los.
• Kev Qhia Txog Kev Ua Haujlwm: Cov kws tshaj lij thiab cov kws tshaj lij & pab pawg muag khoom pabcuam rau kev ua lag luam txawv teb chaws, muab cov kev daws teeb meem raws li qhov xav tau.
• Kev xa khoom sai: 1/2hp txog 50hp cua txias chillers hauv Tshuag rau kev xa khoom tam sim ntawd.
• Cov neeg ua haujlwm ruaj khov: Cov neeg ua haujlwm ruaj khov tuaj yeem ua kom muaj kev ua haujlwm ruaj khov thiab zoo. Txhawm rau kom muaj kev pabcuam zoo thiab kev txhawb nqa tom qab muag zoo.
• Kev pabcuam zoo: Kev teb xov tooj tsis pub dhau 1 teev, kev daws teeb meem yuav muab rau hauv 4 teev, thiab pab pawg neeg teeb tsa thiab txij nkawm txawv teb chaws.
| Qauv (HTS-***) | 40A | 50A | 60A | 80A | 90A | 100A | 110A | 135A | 150A | 170A | ||
| Lub peev xwm txias nominal | 7 ℃ | Kcal/teev | 89870 | 118078 | 126850 | 169764 | 200122 | 215860 | 235554 | 275716 | 336260 | 350192 |
| kw | 104.5 | 137.3 | 147.5 | 197.4 | 232.7 | 257 | 273.9 | 320.6 | 391 | 407.2 | ||
| 12 ℃ | Kcal/teev | 108360 | 142330 | 152822 | 204508 | 241144 | 239720 | 283714 | 332132 | 404200 | 421830 | |
| kw | 126 | 165.5 | 177.7 | 237.8 | 280.4 | 302 | 329.9 | 386.2 | 470 | 490.5 | ||
| Lub zog nkag | kw | 38.7 | 47.6 | 53.3 | 69.8 | 78.3 | 83.7 | 90.6 | 109.4 | 129.8 | 133 | |
| Qhov chaw fais fab | 3PH 380V ~ 415V 50HZ / 60HZ | |||||||||||
| Cov tshuaj txias | Hom | R22 | ||||||||||
| Them nqi | kg | 28 | 35 | 42 | 52 | 60 | 65 | 70 | 84 | 98 | 105 | |
| Kev Tswj | Lub qhov cua sov nthuav dav | |||||||||||
| Lub tshuab cua txias | Hom | Cov ntsia hlau semi-hermermetic | ||||||||||
| lub hwj chim | kw | 35.1 | 44 | 48.5 | 63.4 | 71.9 | 76.5 | 83.4 | 99.8 | 119 | 122.2 | |
| Pib hom | Y-△ | |||||||||||
| Kev tswj hwm peev xwm | % | 0-25-50-75-100 | ||||||||||
| Lub tshuab ua kom sov | Hom | Plhaub thiab lub raj (ss phaj cua sov exchanger) | ||||||||||
| Qhov ntim dej txias | m³/teev | 18 | 23.6 | 25.7 | 34.4 | 40.5 | 43.1 | 46.4 | 55 | 67.3 | 69.5 | |
| Kev poob siab ntawm dej | kPa | 32 | 35 | 38 | 42 | 45 | 42 | 43 | 43.3 | 41 | 41 | |
| Kev sib txuas yeeb nkab | nti | 3 | 3 | 3 | 3 | 3 | 4 | 4 | 4 | 5 | 5 | |
| Lub tshuab cua txias | Hom | cua txias hom high efficiency finned tooj liab raj | ||||||||||
| Lub kiv cua | Hom | Lub kiv cua axial loj thiab suab nrov tsawg | ||||||||||
| Lub zog | kw | 0.6 * 6 | 0.6 * 6 | 0.8 * 6 | 0.8 * 8 | 0.8 * 8 | 0.9 * 8 | 0.9 * 8 | 0.8 * 12 | 0.9 * 12 | 0.9 * 12 | |
| Qhov ntim cua | m³/teev | 53520 | 53520 | 745250 | 99360 | 99360 | 120960 | 120960 | 149040 | 181440 | 181440 | |
| Cov khoom siv kev nyab xeeb | Kev tiv thaiv sab hauv ntawm lub compressor, kev tiv thaiv tam sim no dhau, kev tiv thaiv siab/qis, kev tiv thaiv kub dhau, kev tiv thaiv tus nqi ntws, kev tiv thaiv theem/theem uas ploj lawm, kev tiv thaiv dej txias qis, kev tiv thaiv kev khov, kev tiv thaiv pa tawm kub dhau | |||||||||||
| Qhov Loj | Ntev | mm | 2530 | 2650 | 2950 | 3310 | 4000 | 4300 | 4300 | 5650 | 5980 | 5980 |
| Dav | mm | 1700 xyoo | 1800 xyoo | 1800 xyoo | 1800 xyoo | 2000 xyoo | 2000 xyoo | 2000 xyoo | 2000 xyoo | 2000 xyoo | 2000 xyoo | |
| Qhov siab | mm | Xyoo 1960 | 2060 | 2160 | 2200 | 2050 xyoo | 2170 | 2170 | 2070 | 2170 | 2170 | |
| Qhov hnyav tag nrho | kg | 1300 | 1600 xyoo | 1900 xyoo | 2350 | 2550 | 2700 | 2800 | 2950 | 3100 | 3200 | |
| Khiav qhov hnyav | kg | 1450 xyoo | 1750 xyoo | 2100 | 2550 | 2800 | 2950 | 3050 | 3250 | 3400 | 3500 | |
Cov lus qhia saum toj no yog raws li cov qauv tsim hauv qab no:
Lus Cim: Lub peev xwm txias ntawm R407C chav yuav qis dua 5% piv rau R22 chav Cov tshuaj refrigerant xaiv tau: R407C / R134A Peb muaj cai hloov cov lus qhia yam tsis tau ceeb toom ntxiv. | ||||||||||||
| Qauv (HTS-***) | Xyoo 80AD | 100AD xyoo | 120AD | 160AD xyoo | 180AD xyoo | Xyoo 200AD | 220AD | 270AD | 300AD | 340AD | ||
| Lub peev xwm txias nominal | 7 ℃ | Kcal/teev | 179740 | 236156 | 253700 | 339528 | 400244 | 431720 | 471108 | 551432 | 672520 | 700384 |
| kw | 209 | 274.6 | 295 | 394.8 | 465.4 | 502 | 547.8 | 641.2 | 782 | 814.4 | ||
| 12 ℃ | Kcal/teev | 216720 | 284660 | 305644 | 409016 | 482288 | 519440 | 567428 | 664264 | 808400 | 843660 | |
| kw | 252 | 331 | 355.4 | 475.6 | 560.8 | 604 | 659.8 | 772.4 | 940 | 981 | ||
| Lub zog nkag | kw | 76.6 | 95.2 | 106.6 | 137.6 | 156.6 | 167.4 | 181.2 | 218.8 | 259 | 266 | |
| Qhov chaw fais fab | 3PH 380V ~ 415V 50HZ / 60HZ | |||||||||||
| Cov tshuaj txias | Hom | R22/R407C | ||||||||||
| Them nqi | kg | 28 * 2 | 35 * 2 | 42 * 2 | 52 * 2 | 60 * 2 | 65 * 2 | 70 * 2 | 84 * 2 | 98 * 2 | 105 * 2 | |
| Kev Tswj | Lub qhov cua sov nthuav dav | |||||||||||
| Lub tshuab cua txias | Hom | Cov ntsia hlau semi-hermermetic | ||||||||||
| lub hwj chim | kw | 35.1 * 2 | 44 * 2 | 48.5 * 2 | 63.4 * 2 | 71.9 * 2 | 76.5 * 2 | 83.4 * 2 | 99.8 * 2 | 119 * 2 | 122.2 * 2 | |
| Pib hom | Y-△ | |||||||||||
| Kev tswj hwm peev xwm | % | 0-25-50-75-100 | ||||||||||
| Lub tshuab ua kom sov | Hom | Plhaub thiab lub raj (ss phaj cua sov exchanger) | ||||||||||
| Qhov ntim dej txias | m³/teev | 35.6 | 46.8 | 50.8 | 68 | 80 | 86.3 | 92.8 | 110.6 | 134.5 | 139 | |
| Kev poob siab ntawm dej | kPa | 45 | 43 | 43 | 41 | 42 | 45 | 45 | 42 | 46 | 46 | |
| Kev sib txuas yeeb nkab | nti | 3 | 4 | 4 | 5 | 6 | 6 | 6 | 6 | 8 | 8 | |
| Lub tshuab cua txias | Hom | cua txias hom high efficiency finned tooj liab raj | ||||||||||
| Lub kiv cua | Hom | Lub kiv cua axial loj thiab suab nrov tsawg | ||||||||||
| Lub zog | kw | 0.8 * 8 | 0.9 * 8 | 0.8 * 12 | 0.9 * 12 | 0.8 * 16 | 0.9 * 16 | 0.9 * 16 | 0.8 * 24 | 0.9 * 24 | 0.9 * 24 | |
| Qhov ntim cua | m³/teev | 99360 | 120960 | 149040 | 181440 | 198720 | 241920 | 241920 | 298080 | 362880 | 362880 | |
| Cov khoom siv kev nyab xeeb | Kev tiv thaiv sab hauv ntawm lub compressor, kev tiv thaiv tam sim no dhau, kev tiv thaiv siab/qis, kev tiv thaiv kub dhau, kev tiv thaiv tus nqi ntws, kev tiv thaiv theem/theem uas ploj lawm, kev tiv thaiv dej txias qis, kev tiv thaiv kev khov, kev tiv thaiv pa tawm kub dhau | |||||||||||
| Qhov Loj | Ntev | mm | 4000 | 4300 | 5650 | 5980 | 8000 | 8600 | 8600 | 11300 | 11960 | 11960 |
| Dav | mm | 1800 xyoo | 2000 xyoo | 2000 xyoo | 2000 xyoo | 1800 xyoo | 2000 xyoo | 2000 xyoo | 2000 xyoo | 2000 xyoo | 2000 xyoo | |
| Qhov siab | mm | 2050 xyoo | 2170 | 2070 | 2170 | 2050 xyoo | 2170 | 2170 | 2070 | 2170 | 2170 | |
| Qhov hnyav tag nrho | kg | 2500 | 2950 | 3350 | 4100 | 4350 | 4550 | 4750 | 5200 | 5500 | 5700 | |
| Khiav qhov hnyav | kg | 2800 | 3250 | 3750 | 4500 | 4850 | 5050 | 5250 | 5800 | 6100 | 6300 | |
Cov lus qhia saum toj no yog raws li cov qauv tsim hauv qab no:
Qauv loj dua HTS-150AD yog tsim qauv modular Lus Cim: Lub peev xwm txias ntawm R407C chav yuav qis dua 5% piv rau R22 chav Peb muaj cai hloov cov lus qhia yam tsis tau ceeb toom ntxiv. | ||||||||||||


Q1: Koj puas tuaj yeem pab peb pom zoo tus qauv rau peb qhov project?
A1: Yog, peb muaj engineer los xyuas cov ntsiab lus thiab xaiv cov qauv kom raug rau koj. Raws li cov hauv qab no:
1) Muaj peev xwm txias;
2) Yog tias koj tsis paub, koj tuaj yeem muab tus nqi ntws rau koj lub tshuab, qhov kub thiab txias thiab qhov kub thiab txias tawm ntawm koj qhov siv;
3) Qhov kub thiab txias ib puag ncig;
4) Hom tub yees, R22, R407c lossis lwm yam, pls qhia meej;
5) Lub zog hluav taws xob;
6) Kev lag luam thov;
7) Cov kev cai ntawm cov twj tso kua mis thiab lub zog;
8) Lwm yam kev xav tau tshwj xeeb.
Q2: Yuav ua li cas kom koj cov khoom zoo?
A2: Tag nrho peb cov khoom nrog daim ntawv pov thawj CE thiab peb lub tuam txhab ua raws li ISO900 kev tswj hwm zoo. Peb siv cov khoom siv thoob ntiaj teb nto moo, xws li DANFOSS, COPELAND, SANYO, BITZER, HANBELL compressors, Schneider hluav taws xob Cheebtsam, DANFOSS / EMERSON refrigeration Cheebtsam.
Cov chav tsev yuav raug kuaj xyuas tag nrho ua ntej pob thiab Cov khoom ntim yuav raug kuaj xyuas kom zoo.
Q3: Qhov kev lav phib xaub yog dab tsi?
A3: 1 xyoo lav rau txhua qhov chaw; Tag nrho lub neej ua haujlwm dawb!
Q4: Koj puas yog lub chaw tsim khoom?
A4: Yog, peb muaj ntau tshaj 23 xyoo hauv kev lag luam tub yees. Peb lub Hoobkas nyob hauv Shenzhen; Txais tos tuaj xyuas peb txhua lub sijhawm. Kuj muaj patent rau tus qauv tsim ntawm cov chillers.
Q5: Kuv tuaj yeem tso qhov kev txiav txim li cas?
A5: Send us enquiry via email: sales@szhero-tech.com, call us via Cel number +86 15920056387 directly.