Cua txias hom chiller ntsia hlau

Kev Piav Qhia Luv:

Kev Taw Qhia Txog Khoom HTS-A series industrial chiller feem ntau yog siv rau hauv kev lag luam Yas & Roj Hmab; Nws tuaj yeem tswj tau qhov kub ntawm molding thiab ua kom lub voj voog molding luv dua, ua kom cov khoom zoo dua thiab txhim kho kev ua haujlwm ntau lawm. Lawv kuj siv dav hauv kev ua haujlwm hlau, Mechanical & Engineering, Chemical & Pharmaceutical, Food & Beverage, Laser, Electronics industry, Textile, Electroplate, Semi-conductor testing, Water jet, Vacuum coating, Construction...


Cov Khoom Qhia Txog Khoom

ntim khoom thiab thauj mus los

daim ntawv pov thawj

cov lus nug nquag nug

Kev taw qhia txog khoom

HTS-A series industrial chiller feem ntau yog siv rau hauv kev lag luam Yas & Roj Hmab; Nws tuaj yeem tswj tau qhov kub ntawm molding thiab ua kom lub voj voog molding luv dua, ua kom cov khoom zoo dua thiab txhim kho kev ua haujlwm ntau lawm. Lawv kuj siv dav hauv kev ua haujlwm hlau, Mechanical & Engineering, Chemical & Pharmaceutical, Food & Beverage, Laser, Electronics industry, Textile, Electroplate, Semi-conductor testing, Water jet, Vacuum coating, Construction thiab Military.

 

Tsis yog txhua lub tshuab cua txias zoo ib yam. Yog xav kom txias tau zoo thiab ua haujlwm tau ntev, koj tuaj yeem vam khom rauHERO-TECHntawm Cov Khoom Siv Txias rau txhua yam koj xav tau txias.

HERO-TECH ib txwm nthuav qhia cov kev pabcuam tsim nyog, zoo tshaj plaws thiab kev daws teeb meem.

 

 Daim Ntawv Thov

Kev txias uas ntseeg tau, siv tau ntau yam, thiab ua haujlwm tau zoo.

HERO-TECH chillers xa cov txiaj ntsig rau ntau yam kev siv nrog cov kev xaiv txuag hluav taws xob zoo dua.
Nruab nrab thiab loj industrial txias
Lub tshuab cua txias hauv nruab nrab
Chav txias, chav thermostatic

 

Cov yam ntxwv tsim
Lub npe nrov Compressor
Chav tsev siv lub teb chaws Yelemees BITZER lossis Taiwan HANBELL hom semi-hermetic ntsia hlau compressor. Qhov tseeb tshaj plaws 5 txog 6 patented ntsia hlau rotor profile nrog kev ua haujlwm zoo heev.
Kev tswj hwm lub peev xwm tsis kawg lossis ze ze, muaj zog txuag hluav taws xob, ruaj khov thiab ntsiag to.
Cov txheej txheem tsim khoom siab tshaj plaws uas tau txais daim ntawv pov thawj siab tshaj plaws.
Kev saib xyuas thiab tiv thaiv ntse tag nrho suav nrog kev saib xyuas qhov kub ntawm lub cev muaj zog, kev saib xyuas theem, kev kaw qhov pib dua tes, lub ntsuas kub roj.
Ntau hom refrigerant rau kev xaiv, suav nrog R134A, R407c thiab R22 (R404A, R507c thaum thov).
Kev Tswj Xyuas Microprogramming
Kev lag luam PLC centralized tswj ua ke nrog compressor peev xwm tswj system, precisely saib xyuas.
Kev tiv thaiv sib xyaw rau qhov kub qis, siab/qis siab, tiv thaiv kev khov, theem ploj lawm, tiv thaiv theem, overload, lub cev muaj zog kub dhau, roj sib txawv, hloov pauv dej ntws, pib qeeb.
Cov lus xaiv ua haujlwm, cov ntawv qhia zaub mov ua tus thawj coj, lub xeev khiav ntawm chav tsev yooj yim kho.
Kev Teeb Tsa Yooj Yim, Kev Khiav Txhim Khu Kev Ntseeg Siab
Kev pib ua haujlwm ze ze, txo qhov cuam tshuam rau hluav taws xob.
Kev khiav ruaj khov thiab muaj kev nyab xeeb, kev co qis, yooj yim rau kev teeb tsa.
Cov qauv compact, qhov chaw tsawg dua thiab lub teeb nyob rau hauv qhov hnyav, yooj yim rau kev thauj mus los thiab kev teeb tsa.
Tau txuas hluav taws xob tag nrho, kuaj xyuas thiab sim ua ntej xa khoom, txuag lub sijhawm teeb tsa thiab tus nqi.

· W-puab txhuas fin hom condenser, ua kom muaj chaw sib pauv cua sov txaus hauv qhov me me
· Cov evaporator ua haujlwm tau zoo nrog lub raj tooj liab sab hauv.
· Lub kiv cua axial loj nrog cov hniav hlau. Lub cev muaj zog sib cais los ntawm lub hau ntawm lub vas, kho rau ntawm qhov chaw tso pa tawm los ntawm hlau
· Siemens PLC tswj, LCD kov npo interface.
· Tus qauv tsim them R22, CFC Dawb R407C, R410A, R404A, R134A rau kev xaiv.
·380V-415V/50Hz 3pH rau tus qauv tsim. Tsim sib txawv raws li cov neeg siv khoom thov.

 

Kev pabcuam dav dav

-Pab Pawg Ua Haujlwm: Pab pawg engineering nrog qhov nruab nrab 15 xyoo ntawm kev paub hauv kev lag luam tub yees, pab pawg muag khoom nrog qhov nruab nrab 7 xyoo ntawm kev paub, Pab pawg kev pabcuam nrog qhov nruab nrab 10 xyoo ntawm kev paub.

-Kev daws teeb meem tshwj xeeb yeej ib txwm muab raws li qhov xav tau.

-3 kauj ruam kev tswj xyuas zoo: kev tswj xyuas zoo tuaj, kev tswj xyuas zoo ntawm cov txheej txheem, kev tswj xyuas zoo tawm.

-12 lub hlis lav rau txhua yam khoom. Hauv warranty, txhua qhov teeb meem tshwm sim los ntawm qhov tsis zoo ntawm lub chiller nws tus kheej, kev pabcuam muab kom txog thaum qhov teeb meem daws tau.

 

HTS-A75 yog qhov zoo tshaj plaws rau cov neeg siv khoom

Tsib qhov zoo ntawm HERO-TECH

• Lub zog ntawm hom lag luam: Peb yog cov kws tshaj lij thiab cov neeg muab khoom zoo tshaj plaws ntawm cov tshuab cua txias hauv kev lag luam nrog 20 xyoo ntawm kev paub dhau los.

• Kev Qhia Txog Kev Ua Haujlwm: Cov kws tshaj lij thiab cov kws tshaj lij & pab pawg muag khoom pabcuam rau kev ua lag luam txawv teb chaws, muab cov kev daws teeb meem raws li qhov xav tau.

• Kev xa khoom sai: 1/2hp txog 50hp cua txias chillers hauv Tshuag rau kev xa khoom tam sim ntawd.

• Cov neeg ua haujlwm ruaj khov: Cov neeg ua haujlwm ruaj khov tuaj yeem ua kom muaj kev ua haujlwm ruaj khov thiab zoo. Txhawm rau kom muaj kev pabcuam zoo thiab kev txhawb nqa tom qab muag zoo.

• Kev pabcuam zoo: Kev teb xov tooj tsis pub dhau 1 teev, kev daws teeb meem yuav muab rau hauv 4 teev, thiab pab pawg neeg teeb tsa thiab txij nkawm txawv teb chaws.

 

 

 

 


  • Yav dhau los:
  • Tom ntej no:

  • Qauv (HTS-***)

    40A

    50A

    60A

    80A

    90A

    100A

    110A

    135A

    150A

    170A

    Lub peev xwm txias nominal

    7 ℃

    Kcal/teev

    89870

    118078

    126850

    169764

    200122

    215860

    235554

    275716

    336260

    350192

    kw

    104.5

    137.3

    147.5

    197.4

    232.7

    257

    273.9

    320.6

    391

    407.2

    12 ℃

    Kcal/teev

    108360

    142330

    152822

    204508

    241144

    239720

    283714

    332132

    404200

    421830

    kw

    126

    165.5

    177.7

    237.8

    280.4

    302

    329.9

    386.2

    470

    490.5

    Lub zog nkag

    kw

    38.7

    47.6

    53.3

    69.8

    78.3

    83.7

    90.6

    109.4

    129.8

    133

    Qhov chaw fais fab

    3PH 380V ~ 415V 50HZ / 60HZ

    Cov tshuaj txias Hom

    R22

    Them nqi

    kg

    28

    35

    42

    52

    60

    65

    70

    84

    98

    105

    Kev Tswj

    Lub qhov cua sov nthuav dav

    Lub tshuab cua txias Hom

    Cov ntsia hlau semi-hermermetic

    lub hwj chim

    kw

    35.1

    44

    48.5

    63.4

    71.9

    76.5

    83.4

    99.8

    119

    122.2

    Pib hom

    Y-△

    Kev tswj hwm peev xwm

    %

    0-25-50-75-100

    Lub tshuab ua kom sov Hom

    Plhaub thiab lub raj (ss phaj cua sov exchanger)

    Qhov ntim dej txias

    m³/teev

    18

    23.6

    25.7

    34.4

    40.5

    43.1

    46.4

    55

    67.3

    69.5

    Kev poob siab ntawm dej

    kPa

    32

    35

    38

    42

    45

    42

    43

    43.3

    41

    41

    Kev sib txuas yeeb nkab

    nti

    3

    3

    3

    3

    3

    4

    4

    4

    5

    5

    Lub tshuab cua txias Hom

    cua txias hom high efficiency finned tooj liab raj

    Lub kiv cua Hom

    Lub kiv cua axial loj thiab suab nrov tsawg

    Lub zog

    kw

    0.6 * 6

    0.6 * 6

    0.8 * 6

    0.8 * 8

    0.8 * 8

    0.9 * 8

    0.9 * 8

    0.8 * 12

    0.9 * 12

    0.9 * 12

    Qhov ntim cua

    m³/teev

    53520

    53520

    745250

    99360

    99360

    120960

    120960

    149040

    181440

    181440

    Cov khoom siv kev nyab xeeb

    Kev tiv thaiv sab hauv ntawm lub compressor, kev tiv thaiv tam sim no dhau, kev tiv thaiv siab/qis, kev tiv thaiv kub dhau, kev tiv thaiv tus nqi ntws, kev tiv thaiv theem/theem uas ploj lawm, kev tiv thaiv dej txias qis, kev tiv thaiv kev khov, kev tiv thaiv pa tawm kub dhau

    Qhov Loj Ntev

    mm

    2530

    2650

    2950

    3310

    4000

    4300

    4300

    5650

    5980

    5980

    Dav

    mm

    1700 xyoo

    1800 xyoo

    1800 xyoo

    1800 xyoo

    2000 xyoo

    2000 xyoo

    2000 xyoo

    2000 xyoo

    2000 xyoo

    2000 xyoo

    Qhov siab

    mm

    Xyoo 1960

    2060

    2160

    2200

    2050 xyoo

    2170

    2170

    2070

    2170

    2170

    Qhov hnyav tag nrho

    kg

    1300

    1600 xyoo

    1900 xyoo

    2350

    2550

    2700

    2800

    2950

    3100

    3200

    Khiav qhov hnyav

    kg

    1450 xyoo

    1750 xyoo

    2100

    2550

    2800

    2950

    3050

    3250

    3400

    3500

    Cov lus qhia saum toj no yog raws li cov qauv tsim hauv qab no:

    1. Qhov kub ntawm cov dej nkag/qhov hluav taws xob txias 12 ℃ / 7%
    2. Qhov kub ntawm qhov dej nkag/qhov hluav taws xob txias 30%/35%

    Lus Cim: Lub peev xwm txias ntawm R407C chav yuav qis dua 5% piv rau R22 chav

    Cov tshuaj refrigerant xaiv tau: R407C / R134A

    Peb muaj cai hloov cov lus qhia yam tsis tau ceeb toom ntxiv.

    Qauv (HTS-***)

    Xyoo 80AD

    100AD xyoo

    120AD

    160AD xyoo

    180AD xyoo

    Xyoo 200AD

    220AD

    270AD

    300AD

    340AD

    Lub peev xwm txias nominal

    7 ℃

    Kcal/teev

    179740

    236156

    253700

    339528

    400244

    431720

    471108

    551432

    672520

    700384

    kw

    209

    274.6

    295

    394.8

    465.4

    502

    547.8

    641.2

    782

    814.4

    12 ℃

    Kcal/teev

    216720

    284660

    305644

    409016

    482288

    519440

    567428

    664264

    808400

    843660

    kw

    252

    331

    355.4

    475.6

    560.8

    604

    659.8

    772.4

    940

    981

    Lub zog nkag

    kw

    76.6

    95.2

    106.6

    137.6

    156.6

    167.4

    181.2

    218.8

    259

    266

    Qhov chaw fais fab

    3PH 380V ~ 415V 50HZ / 60HZ

    Cov tshuaj txias Hom

    R22/R407C

    Them nqi

    kg

    28 * 2

    35 * 2

    42 * 2

    52 * 2

    60 * 2

    65 * 2

    70 * 2

    84 * 2

    98 * 2

    105 * 2

    Kev Tswj

    Lub qhov cua sov nthuav dav

    Lub tshuab cua txias Hom

    Cov ntsia hlau semi-hermermetic

    lub hwj chim

    kw

    35.1 * 2

    44 * 2

    48.5 * 2

    63.4 * 2

    71.9 * 2

    76.5 * 2

    83.4 * 2

    99.8 * 2

    119 * 2

    122.2 * 2

    Pib hom

    Y-△

    Kev tswj hwm peev xwm

    %

    0-25-50-75-100

    Lub tshuab ua kom sov Hom

    Plhaub thiab lub raj (ss phaj cua sov exchanger)

    Qhov ntim dej txias

    m³/teev

    35.6

    46.8

    50.8

    68

    80

    86.3

    92.8

    110.6

    134.5

    139

    Kev poob siab ntawm dej

    kPa

    45

    43

    43

    41

    42

    45

    45

    42

    46

    46

    Kev sib txuas yeeb nkab

    nti

    3

    4

    4

    5

    6

    6

    6

    6

    8

    8

    Lub tshuab cua txias Hom

    cua txias hom high efficiency finned tooj liab raj

    Lub kiv cua Hom

    Lub kiv cua axial loj thiab suab nrov tsawg

    Lub zog

    kw

    0.8 * 8

    0.9 * 8

    0.8 * 12

    0.9 * 12

    0.8 * 16

    0.9 * 16

    0.9 * 16

    0.8 * 24

    0.9 * 24

    0.9 * 24

    Qhov ntim cua

    m³/teev

    99360

    120960

    149040

    181440

    198720

    241920

    241920

    298080

    362880

    362880

    Cov khoom siv kev nyab xeeb

    Kev tiv thaiv sab hauv ntawm lub compressor, kev tiv thaiv tam sim no dhau, kev tiv thaiv siab/qis, kev tiv thaiv kub dhau, kev tiv thaiv tus nqi ntws, kev tiv thaiv theem/theem uas ploj lawm, kev tiv thaiv dej txias qis, kev tiv thaiv kev khov, kev tiv thaiv pa tawm kub dhau

    Qhov Loj Ntev

    mm

    4000

    4300

    5650

    5980

    8000

    8600

    8600

    11300

    11960

    11960

    Dav

    mm

    1800 xyoo

    2000 xyoo

    2000 xyoo

    2000 xyoo

    1800 xyoo

    2000 xyoo

    2000 xyoo

    2000 xyoo

    2000 xyoo

    2000 xyoo

    Qhov siab

    mm

    2050 xyoo

    2170

    2070

    2170

    2050 xyoo

    2170

    2170

    2070

    2170

    2170

    Qhov hnyav tag nrho

    kg

    2500

    2950

    3350

    4100

    4350

    4550

    4750

    5200

    5500

    5700

    Khiav qhov hnyav

    kg

    2800

    3250

    3750

    4500

    4850

    5050

    5250

    5800

    6100

    6300

    Cov lus qhia saum toj no yog raws li cov qauv tsim hauv qab no:

    1. Qhov kub ntawm cov dej nkag/qhov hluav taws xob txias 12 ℃/7 ℃
    2. Qhov kub ntawm cua txias nkag/tawm 30℃/38℃

    Qauv loj dua HTS-150AD yog tsim qauv modular

    Lus Cim: Lub peev xwm txias ntawm R407C chav yuav qis dua 5% piv rau R22 chav

    Peb muaj cai hloov cov lus qhia yam tsis tau ceeb toom ntxiv.

    Kev ntim khoom xa tuaj

    daim ntawv pov thawj

    Q1: Koj puas tuaj yeem pab peb pom zoo tus qauv rau peb qhov project?
    A1: Yog, peb muaj engineer los xyuas cov ntsiab lus thiab xaiv cov qauv kom raug rau koj. Raws li cov hauv qab no:
    1) Muaj peev xwm txias;
    2) Yog tias koj tsis paub, koj tuaj yeem muab tus nqi ntws rau koj lub tshuab, qhov kub thiab txias thiab qhov kub thiab txias tawm ntawm koj qhov siv;
    3) Qhov kub thiab txias ib puag ncig;
    4) Hom tub yees, R22, R407c lossis lwm yam, pls qhia meej;
    5) Lub zog hluav taws xob;
    6) Kev lag luam thov;
    7) Cov kev cai ntawm cov twj tso kua mis thiab lub zog;
    8) Lwm yam kev xav tau tshwj xeeb.

     

     

    Q2: Yuav ua li cas kom koj cov khoom zoo?
    A2: Tag nrho peb cov khoom nrog daim ntawv pov thawj CE thiab peb lub tuam txhab ua raws li ISO900 kev tswj hwm zoo. Peb siv cov khoom siv thoob ntiaj teb nto moo, xws li DANFOSS, COPELAND, SANYO, BITZER, HANBELL compressors, Schneider hluav taws xob Cheebtsam, DANFOSS / EMERSON refrigeration Cheebtsam.
    Cov chav tsev yuav raug kuaj xyuas tag nrho ua ntej pob thiab Cov khoom ntim yuav raug kuaj xyuas kom zoo.

     

     

    Q3: Qhov kev lav phib xaub yog dab tsi?
    A3: 1 xyoo lav rau txhua qhov chaw; Tag nrho lub neej ua haujlwm dawb!

     

     

    Q4: Koj puas yog lub chaw tsim khoom?
    A4: Yog, peb muaj ntau tshaj 23 xyoo hauv kev lag luam tub yees. Peb lub Hoobkas nyob hauv Shenzhen; Txais tos tuaj xyuas peb txhua lub sijhawm. Kuj muaj patent rau tus qauv tsim ntawm cov chillers.

     

     

    Q5: Kuv tuaj yeem tso qhov kev txiav txim li cas?
    A5: Send us enquiry via email: sales@szhero-tech.com, call us via Cel number +86 15920056387 directly.

    COV KHOOM SIV TXWV