Home > Products > Glycol air-cooled Screw Chiller >

Screw Type Air-cooled Glycol Chiller HTSL-140A

Screw Type Air-cooled Glycol Chiller HTSL-140A

Screw Type Air-cooled Glycol Chiller HTSL-140A
Screw Type Air-cooled Glycol Chiller HTSL-140AScrew Type Air-cooled Glycol Chiller HTSL-140AScrew Type Air-cooled Glycol Chiller HTSL-140AScrew Type Air-cooled Glycol Chiller HTSL-140AScrew Type Air-cooled Glycol Chiller HTSL-140A
CategoriesGlycol air-cooled Screw Chiller
AlbumView larger image
BrandHERO-TECH
ModelScrew type Air-cooled Glycol Chiller HTSL-140A
Compressor brandHANBELL/BITZER
Compressor typesemi-hermetic screw compressor
FanLow noise
Power3ph 380v 50hz and 60HZ for option
Temperature displayTOUCH SCREEN
Temperature range-35C to 5C
RefrigerantR22, R407C
ControlSIEMENS PLC
FOB portSHENZHEN or any pointed port in China
Terms of PaymentL/C, D/P, Western Union, T/T
Update Time2019-01-20
Detail Information

HERO-TECH 140hp air cooled screw chiller for low temperature solution


HERO-TECH Air cooled screw chillers with featured advantages as following,

l  Low cost

l  Energy saving

l  Easy connection

l  Easy and convenient maintenance

 

l  Power:3PH 380-415V 50HZ

Well Known BrandCompressor

¨      Unit adopts Germany BITZER or Taiwan HANDBELL brand semi-hermetic screw compressor. The latest 5 to 6 patented screw rotorprofile with excellent efficiency.

¨      Adjustable infinite or closely stepped capacitycontrol, features energy efficient, stable and quiet running.

¨      Most advanced patented highest precisionmanufacturing process.

¨      Built-in full intelligent monitoring andprotection including thermal motor temperature monitoring, phase sequencemonitoring, manual reset lock-out, oil temperature sensor.

¨      Wide range of refrigerant for option, includingR22 and R134a, R407c.

MicroprogrammingControl System

¨      Industrial PLC centralized control combined withcompressor capacity control system, precisely monitor.

¨      Integrated protection for low temperature,high/low pressure, anti-freezing, phase missing, anti-phase, overload, motorover temperature, oil differential, flow switch, start up latency.

¨      Optional operation language, menu leading, unitrunning state easy to adjust.

Easy Installation,Reliable Running

¨      Closely stepped start-up, minimize impact toelectricity.

¨      Steady and safe running, low vibration, easy forinstallation.

¨      Compact structure, less space demand and lightin weight, easy for transport and installation.

¨      Completely wired, inspected and testedpre-delivery, saving installation time and cost.

 


l  3PH 220V/240V/380V/440V/480V/560V 60HZ

l  Above 40C high ambient temperature

 Soft starting

l  Plate heat exchanger

l  Electronic expansion valve

l  Nonferrous water loop

l  Pump: Minamoto Iron pump or high pressure pump


HTSL-ASeries Low Temperature Screw Type Chiller Technical Specifications

Model

HTSL-140A

Nominal cooling capacity

    -10℃

KW

239

    -20℃

159

    -30℃

118

Input power

KW

142.6

Power source

 

3PH  380V~415V/50HZ

Refrigerant

Type

 

R22/R404A

Charge

kg

109

Control

 

Thermostatic expansion valve

Compressor

Type

 

Semi-hermetic screw

Motor Power

kw

133

Start mode

 

Y-△

Capacity control

%

0-25-50-75-100

Evaporator

Type

 

Shell and tube

Coolant volume

-10℃

 

m3/h

41.4

-20℃

27.3

-30℃

20.3

Water pressure drop

KPa

41

Pipe connection

Inch

5

Condenser

Type

 

Air cooled type high efficiency finned copper tube

Fan information

Type

 

Big volume & low noise axil fan

Motor power

KW

1.2×8

Air volume

m3/h

105000

Safety devices

Inner thermostat for compressor motor, unit overload relay, high&low pressure switch,  freeze protection thermostat, reverse phase protection relay,discharge gas thermostat, flow switch.

Dimension

Length

mm

5500

Width

mm

2100

Height

mm

2200

Net weight

KG

3250

Running weight

KG

3550

           

NOTE:The specifications based on the following design conditions:

l  Condensingtemperature: 50

l  Cooling airinlet/outlet temperature: 30/38

Wereserve the right to modify the specifications without further notice.